{"title":"Mammography","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThis category includes phantoms designed for acceptance and constancy testing of mammography systems. The models support the evaluation of image quality parameters, such as contrast, spatial resolution, and the detection of small structures, ensuring consistent performance and regulatory compliance.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e","products":[{"product_id":"pro-mam-accreditation-ff","title":"Pro-MAM ACR FF","description":"\u003ch2 class=\"p1\"\u003e\n\u003cmeta charset=\"utf-8\"\u003eACR-Approved. Full-field coverage for digital mammography QA and accreditation testing.\u003c\/h2\u003e\n\u003cp class=\"p1\"\u003e\u003cmeta charset=\"utf-8\"\u003eEnsure your digital mammography system meets \u003cstrong\u003eACR Mammography Accreditation Program\u003c\/strong\u003e and \u003cstrong\u003eIEC 61223-3-2 requirements\u003c\/strong\u003e with the \u003cstrong\u003eFull Field Phantom\u003c\/strong\u003e – designed for comprehensive, full-field QA and accreditation testing.\u003c\/p\u003e\n\u003cp class=\"p3\"\u003eThis phantom is designed to simulate the \u003cspan class=\"s2\"\u003e\u003cb\u003eappearance of real breast structures\u003c\/b\u003e\u003c\/span\u003e, including \u003cspan class=\"s2\"\u003e\u003cb\u003emicro-calcifications\u003c\/b\u003e\u003c\/span\u003e, \u003cspan class=\"s2\"\u003e\u003cb\u003efibrous tissue in ducts\u003c\/b\u003e\u003c\/span\u003e, and \u003cspan class=\"s2\"\u003e\u003cb\u003etumor-like masses\u003c\/b\u003e\u003c\/span\u003e, \u003cmeta charset=\"utf-8\"\u003eenabling systematic verification of system performance across micro-calcification detection, spatial resolution, and contrast sensitivity.\u003c\/p\u003e\n\u003cp class=\"p3\"\u003eLarger than the standard Pro-MAM Phantom, the \u003cspan class=\"s2\"\u003e\u003cb\u003eFull Field (FF)\u003c\/b\u003e\u003c\/span\u003e version provides \u003cspan class=\"s2\"\u003e\u003cb\u003ecomplete coverage of the image receptor\u003c\/b\u003e\u003c\/span\u003e, minimizing scatter and enhancing the accuracy of system evaluation.\u003c\/p\u003e\n\u003cp class=\"p3\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\u003cspan\u003eWhat if ACR accreditation could be faster, simpler, and fully documented?\u003cspan class=\"white-space-pre\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"p3\"\u003e\u003cspan\u003eThat’s exactly what Diagnomatic\u003c\/span\u003e\u003cspan class=\"white-space-pre\"\u003e \u003c\/span\u003e\u003cspan\u003eis built to deliver. Our \u003cstrong\u003eQA automation platform\u003c\/strong\u003e takes the complexity out of the process so you can focus on what really matters, your patients.\u003c\/span\u003e\u003cspan class=\"white-space-pre\"\u003e \u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p3\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0725\/0640\/9300\/files\/soft.png?v=1774894182\" alt=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p3\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eWith Diagnomatic, you can:\u003c\/span\u003e\u003cspan class=\"white-space-pre\"\u003e \u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e✅ Complete QA evaluations automatically – no manual measurements\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e✅ \u003cmeta charset=\"utf-8\"\u003eInstantly generate reports compliant with ACR Mammography Accreditation Program and IEC 61223-3-2\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e✅ Keep all results securely stored online and accessible anytime\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e✅ \u003cmeta charset=\"utf-8\"\u003eReduce documentation time, minimize human error, and maintain consistent compliance records\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eDiagnomatic works seamlessly with the Pro-MAM Accreditation FF phantom, giving you everything you need to approach accreditation with confidence.\u003c\/span\u003e\u003cspan class=\"white-space-pre\"\u003e \u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e👉 Buyers of the Pro-MAM Accreditation FF phantom get \u003cstrong\u003e2 months\u003c\/strong\u003e of Diagnomatic access \u003cstrong\u003efree\u003c\/strong\u003e, so you can streamline reporting and compliance from day one.\u003c\/span\u003e\u003cspan class=\"white-space-pre\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p3\"\u003e \u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2\u003eKey Benefits:\u003c\/h2\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003eFull detector coverage\u003c\/b\u003e\u003c\/span\u003e – ideal for large-format digital mammography systems\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e✅ \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eACR-Approved \u0026amp; CE certified\u003c\/b\u003e\u003c\/span\u003e – ensures regulatory compliance and readiness for accreditation\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e✅ \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eClinically realistic simulation\u003c\/b\u003e\u003c\/span\u003e – replicates a 42 mm compressed breast with 50\/50 glandular\/adipose composition\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e✅ \u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eEvaluates micro-calcification detectability\u003c\/strong\u003e down to 0.14 mm and ductal structures down to 0.30 mm\u003c\/span\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e✅ \u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003eProtective carrying case included\u003c\/strong\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e – easy transport and storage\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003e\u003c\/span\u003e\u003cb\u003eCustomizable to your specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2\u003eSimulates:\u003c\/h2\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003eMicro-calcifications\u003c\/b\u003e\u003c\/span\u003e – aluminum oxide specks: 0.32–0.14 mm\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e✅ \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eFibrous structures\u003c\/b\u003e\u003c\/span\u003e – nylon fibrils: 0.89–0.30 mm\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e✅ \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eTumor-like masses\u003c\/b\u003e\u003c\/span\u003e – PMMA: 1.00–0.20 mm thick\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Distribution of test objects in the Pro-MAM Accreditation FF phantom\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0725\/0640\/9300\/files\/60f7d8849d72cd623769be66_WoskPro-MAMAccreditationFF_480x480.jpg?v=1679377570\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003ch2\u003eTechnical Data:\u003c\/h2\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003eDimensions: \u003c\/span\u003e\u003cb\u003e311.2 x 190.5 x 41.3 mm\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003e\u003c\/b\u003eSimulated breast thickness: \u003cspan class=\"s1\"\u003e\u003cb\u003e42 mm\u003c\/b\u003e\u003c\/span\u003e, 50% glandular \/ 50% adipose\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e✅ \u003c\/span\u003eWax insert with precision-placed targets\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e✅ \u003c\/span\u003eProtective \u003cspan class=\"s1\"\u003e\u003cb\u003ecarrying case\u003c\/b\u003e\u003c\/span\u003e included\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eStandards Compliance:\u003c\/h2\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003eACR Mammography Accreditation Program Requirements\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅  \u003c\/span\u003e\u003c\/b\u003e\u003cb\u003eIEC 61223-3-2\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003cb\u003eCE Certified\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003e\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003eDetailed user manual included – with \u003c\/span\u003e\u003cb\u003eclear guidelines for test execution and results assessment\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eFull-field validation. ACR-compliant results.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cmeta charset=\"utf-8\"\u003eGet the ACR-approved phantom built to meet the exact requirements of the ACR Mammography Accreditation Program.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eOrder your Full Field Mammography Phantom today and \u003cmeta charset=\"utf-8\"\u003eensure your system meets ACR Mammography Accreditation Program requirements.\u003c\/b\u003e\u003c\/p\u003e","brand":"Diagnomatic","offers":[{"title":"Default Title","offer_id":46371439214932,"sku":"03-502","price":1200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/0640\/9300\/files\/Pro-MAMACRFF_3bfdd653-3d22-4e01-b168-3d0b927af670.webp?v=1777566969"},{"product_id":"pro-mam-accreditation","title":"Pro-MAM ACR","description":"\u003ch2 class=\"p1\"\u003eACR-Approved. Clinically relevant. Designed for confidence.\u003cb\u003e\u003c\/b\u003e\n\u003c\/h2\u003e\n\u003cp class=\"p3\"\u003eEnsure your mammographic system is ready for \u003cspan class=\"s1\"\u003e\u003cb\u003eACR accreditation and daily quality control\u003c\/b\u003e\u003c\/span\u003e with the \u003cspan class=\"s1\"\u003e\u003cb\u003ePro-MAM Accreditation Phantom\u003c\/b\u003e\u003c\/span\u003e – a powerful tool for verifying your system’s ability to detect the smallest, most critical breast structures.\u003c\/p\u003e\n\u003cp class=\"p3\"\u003eFrom \u003cspan class=\"s1\"\u003e\u003cb\u003ecalcifications and fibrous strands\u003c\/b\u003e\u003c\/span\u003e to \u003cspan class=\"s1\"\u003e\u003cb\u003etumor-like masses\u003c\/b\u003e\u003c\/span\u003e, the Pro-MAM Phantom simulates real clinical scenarios in a highly reproducible and standardized way, so you can test with confidence and \u003cmeta charset=\"utf-8\"\u003emeet accreditation requirements reliably.\u003c\/p\u003e\n\u003ch2 class=\"p3\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch2 class=\"p3\"\u003e\u003cspan\u003eWhat if ACR accreditation could be faster, simpler, and fully documented?\u003cspan class=\"white-space-pre\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"p3\"\u003e\u003cspan\u003eThat’s exactly what Diagnomatic\u003c\/span\u003e\u003cspan class=\"white-space-pre\"\u003e \u003c\/span\u003e\u003cspan\u003eis built to deliver. Our \u003cstrong\u003eQA automation platform\u003c\/strong\u003e takes the complexity out of the process so you can focus on what really matters, your patients.\u003c\/span\u003e\u003cspan class=\"white-space-pre\"\u003e \u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p3\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0725\/0640\/9300\/files\/soft.png?v=1774894182\" alt=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p3\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eWith Diagnomatic, you can:\u003c\/span\u003e\u003cspan class=\"white-space-pre\"\u003e \u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e✅ Complete QA evaluations automatically – no manual measurements\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e✅ \u003cmeta charset=\"utf-8\"\u003eInstantly generate reports compliant with ACR Mammography Accreditation Program and IEC 61223-3-2\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e✅ Keep all results securely stored online and accessible anytime\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e✅ \u003cmeta charset=\"utf-8\"\u003eReduce documentation time, minimize human error, and maintain consistent compliance records\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003eDiagnomatic works seamlessly with the Pro-MAM Accreditation phantom, giving you everything you need to approach accreditation with confidence.\u003c\/span\u003e\u003cspan class=\"white-space-pre\"\u003e \u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e👉 Buyers of the Pro-MAM Accreditation phantom get \u003cstrong\u003e2 months\u003c\/strong\u003e of Diagnomatic access \u003cstrong\u003efree\u003c\/strong\u003e, so you can streamline reporting and compliance from day one.\u003c\/span\u003e\u003cspan class=\"white-space-pre\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p3\"\u003e \u003c\/p\u003e\n\u003ch2\u003eWhy choose the Pro-MAM Accreditation Phantom?\u003c\/h2\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003eACR-Approved \u0026amp; CE Certified\u003c\/b\u003e\u003c\/span\u003e – full compliance with accreditation standards\u003cbr\u003e\u003cspan\u003e✅ \u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eClinically relevant structures\u003c\/b\u003e\u003c\/span\u003e – mimics calcifications, ducts, and lesions\u003cbr\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003eAccurate, repeatable results\u003c\/b\u003e\u003c\/span\u003e – assess image quality and system performance in one step\u003cbr\u003e\u003cb\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003eComfortable, protective carrying case included\u003cbr\u003e\u003c\/b\u003e\u003cb\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003eCan be customized\u003c\/b\u003e\u003c\/span\u003e to meet your specifications\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2\u003eSimulates:\u003c\/h2\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003eCalcifications\u003c\/b\u003e\u003c\/span\u003e – aluminum oxide specks: 0.54–0.16 mm\u003cbr\u003e\u003cb\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003eFibrous calcifications in ducts\u003c\/b\u003e\u003cspan class=\"s1\"\u003e – nylon fibrils: 1.56–0.40 mm\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003eTumor masses\u003c\/b\u003e\u003c\/span\u003e – PMMA discs: 2.00–0.25 mm thick\u003cbr\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003eCompressed breast\u003c\/b\u003e\u003c\/span\u003e – 42 mm equivalent (average glandular\/adipose mix)\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0725\/0640\/9300\/files\/Pro-MAM_Accreditation_Pattern_480x480.webp?v=1679383061\" alt=\"Distribution of test subjects in the Pro-MAM Accreditation phantom\"\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2\u003eTechnical data:\u003c\/h2\u003e\n\u003cp class=\"p1\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e✅ \u003c\/span\u003eDimensions: 101.5 x 108.0 x 44.0 mm\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e✅ \u003c\/span\u003eTotal PMMA thickness: 36.75 mm\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e✅ \u003c\/span\u003eWax insert thickness: 7.25 mm\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e✅ \u003c\/span\u003ePMMA contrast disc: 10 mm diameter, 4 mm thick\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2\u003eComplies with:\u003c\/h2\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003eACR Mammography Accreditation Program (May 4, 2012)\u003cbr\u003e\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003cb\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003eIEC 61223-3-2\u003cbr\u003e\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003cb\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003eCE certified\u003cbr\u003e\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003cspan class=\"s1\"\u003e\u003cb\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003eUser manual included\u003c\/b\u003e\u003c\/span\u003e – with step-by-step testing and evaluation guidelines\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2\u003eWhat’s included:\u003c\/h2\u003e\n\u003cp class=\"p1\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e✅ \u003c\/span\u003ePro-MAM Accreditation Phantom\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e✅ \u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003e2 months\u003c\/strong\u003e of \u003cstrong\u003efree\u003c\/strong\u003e Diagnomatic access\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"s1\"\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e✅ \u003c\/span\u003eDurable \u003c\/span\u003e\u003cb\u003ecarrying case\u003cbr\u003e\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e✅ \u003c\/span\u003eFull documentation\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eTest with accuracy. Accredit with confidence.\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cmeta charset=\"utf-8\"\u003eGet the ACR-approved phantom built to meet the exact requirements of the ACR Mammography Accreditation Program.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eOrder your Pro-MAM Accreditation Phantom today and ensure your imaging system is ready to deliver.\u003c\/b\u003e\u003c\/p\u003e","brand":"Diagnomatic","offers":[{"title":"Default Title","offer_id":46371511796052,"sku":"03-501","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/0640\/9300\/files\/Pro-MAMACR_95208261-b754-4491-ae08-e31f15c45b61.webp?v=1777566951"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/0640\/9300\/collections\/mammo4.webp?v=1777300012","url":"https:\/\/shop.diagnomatic.com\/collections\/mammography.oembed","provider":"Diagnomatic","version":"1.0","type":"link"}