{"title":"Nuclear Medicine","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003ePhantoms in this section support QA procedures in nuclear medicine, including planar imaging, SPECT, and PET. They are designed to evaluate performance parameters such as uniformity, spatial resolution, sensitivity, and quantification accuracy.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"pro-nm-acr-performance-pet-lid","title":"Pro-NM ACR Performance PET","description":"\u003ch2\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003eACR-Approved. AAPM Report 177 compliant. Built for PET accreditation testing.\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRefillable cylinder design for flexible hot\/cold lesion configuration.\u003c\/strong\u003e\u003cbr\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe Pro-NM ACR Performance PET Lid is a PET imaging phantom designed to meet ACR Nuclear Medicine and PET Accreditation Program requirements. It combines three test sections in a single PMMA cylinder: a cold rod insert for spatial resolution assessment (4.8–12.7 mm rods), a uniform section for SUV calibration and background uniformity testing, and an ACR-compliant PET Lid with refillable thin-walled cylinders for hot and cold lesion contrast evaluation.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch3 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eRefillable cylinders, not solid spheres\u003c\/h3\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eUnlike standard PET phantoms with fixed-activity solid spheres, the Pro-NM PET Lid uses \u003cstrong\u003erefillable thin-walled cylinders\u003c\/strong\u003e that allow you to set custom hot-to-background activity ratios for each test. This gives you flexibility to:\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-pre-wrap leading-[1.7]\"\u003e✅ Match your facility's clinical FDG protocols\u003cbr\u003e✅ Adjust contrast ratios for harmonization studies\u003cbr\u003e✅ Reuse the phantom across multiple test scenarios without replacing inserts\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-pre-wrap leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch3 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eWhy choose the Pro-NM ACR Performance PET Lid?\u003c\/h3\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eACR-Approved\u003c\/strong\u003e – meets ACR Nuclear Medicine and PET Accreditation Program requirements\u003cbr\u003e✅ \u003cstrong\u003eAAPM Report 177 compliant\u003c\/strong\u003e – aligned with current US medical physics guidelines\u003cbr\u003e✅ \u003cstrong\u003eReferenced in ACR PET Quality Control Manual (2025)\u003c\/strong\u003e – documented test protocols included\u003cbr\u003e✅ \u003cstrong\u003eRefillable cylinder configuration\u003c\/strong\u003e – flexible activity ratios for clinical and research protocols\u003cbr\u003e✅ \u003cstrong\u003eStandard ACR rod insert\u003c\/strong\u003e – 4.8, 6.4, 7.9, 9.5, 11.1, and 12.7 mm rods for spatial resolution assessment\u003cbr\u003e✅ \u003cstrong\u003eCE marked\u003c\/strong\u003e – EU regulatory compliance\u003cbr\u003e✅ \u003cstrong\u003eDetailed user manual\u003c\/strong\u003e – step-by-step test execution and results assessment\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eStandards compliance:\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003e✅ ACR Nuclear Medicine and PET Accreditation Program requirements\u003cbr\u003e✅ AAPM Report No. 177\u003cbr\u003e✅ Referenced in \u003cem\u003ePositron Emission Tomography Quality Control Manual\u003c\/em\u003e (ACR, 2025)\u003cbr\u003e✅ CE marked\u003cbr\u003e✅ Comprehensive user manual with step-by-step test execution and evaluation criteria\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2\u003eTechnical specs:\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eMain cylinder (PMMA)\u003c\/strong\u003e\u003cem\u003e\u003cbr\u003e\u003c\/em\u003e✅ Inside diameter: 209.6 mm (8¼\")\u003cbr\u003e✅ Inside height: 184 mm\u003cbr\u003e✅ Wall thickness: 6.4 mm (¼\")\u003cbr\u003e✅ HU range: 110–135\u003cbr\u003e✅ Volume (empty): 6.35 L\u003cbr\u003e✅ Volume with cold rod insert: 5.55 L\u003cbr\u003e✅ Volume with PET Lid (no insert): 6.2 L\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eCold rod insert\u003c\/strong\u003e\u003cem\u003e\u003cbr\u003e\u003c\/em\u003e✅ Rod diameters: 4.8, 6.4, 7.9, 9.5, 11.1, 12.7 mm\u003cbr\u003e✅ Rod height: 88 mm\u003cbr\u003e✅ Standard ACR configuration and orientation\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003ePET Lid – cylindrical samples\u003c\/strong\u003e\u003cem\u003e\u003cbr\u003e\u003c\/em\u003e✅ Refillable thin-walled cylinders: 8 mm (1.9 mL), 12 mm (4.3 mL), 16 mm (7.7 mL), 25 mm (18.7 mL ×3)\u003cbr\u003e✅ Air \u0026amp; water cylinders: 25 mm internal diameter, 29.4 mm external, 38.1 mm height\u003cbr\u003e✅ Teflon® cylinder: 25 mm diameter, 38.1 mm height (bone-equivalent reference)\u003cbr\u003e✅ Cylinder placement radius: ~67 mm (134 mm diameter)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eOptimize your phantom preparation workflow\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eTomographic uniformity testing depends on a fully homogeneous radioactive solution (typically Tc-99m). Pair your Pro-NM ACR Performance PET lid Phantom with the \u003cstrong\u003ePro-NM Automixer\u003c\/strong\u003e for:\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-pre-wrap leading-[1.7]\"\u003e✅ Hands-free, automated phantom rotation\u003cbr\u003e✅ Reduced personnel radiation exposure (ALARA-compliant workflow)\u003cbr\u003e✅ Consistent, reproducible solution homogeneity\u003cbr\u003e✅ Mixing complete in 5–10 minutes\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003ca href=\"https:\/\/shop.diagnomatic.com\/products\/pro-nm-automixer\" title=\"Pro-NM AutoMixer\" rel=\"noopener\" target=\"_blank\"\u003e→ See the Pro-NM Automixer\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eWhat's included:\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e✅ \u003cmeta charset=\"utf-8\"\u003ePro-NM ACR Performance PET Lid phantom (cylinder + cold rod insert + PET Lid)\u003c\/span\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e✅ \u003cmeta charset=\"utf-8\"\u003eUser manual with test protocols\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eDelivery time:\u003c\/h2\u003e\n\u003cp class=\"p3\"\u003e\u003cspan class=\"s2\"\u003e\u003cb\u003e2–3 weeks\u003c\/b\u003e\u003c\/span\u003e from order confirmation\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003ePET accreditation testing with documented protocols.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eGet the ACR-approved phantom built to meet the exact requirements of the ACR Nuclear Medicine and PET Accreditation Program.\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eOrder your \u003cmeta charset=\"utf-8\"\u003ePro-NM ACR Performance PET Lid phantom today.\u003c\/b\u003e\u003c\/p\u003e","brand":"Diagnomatic","offers":[{"title":"Default Title","offer_id":55645539434836,"sku":null,"price":2600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/0640\/9300\/files\/pro-nm_acr_performance_pet_268f43e7-27d8-4489-a940-aadbc553cc9a.webp?v=1777566905"},{"product_id":"pro-nm-automixer","title":"Pro-NM Automixer","description":"\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eAutomated phantom mixing for PET and SPECT QA.\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eImprove solution homogeneity, reduce preparation time, and lower radiation exposure to personnel.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe Pro-NM Automixer is an automatic table mixer designed for preparing homogeneous radioactive solutions in cylindrical nuclear medicine phantoms – including ACR PET phantoms, NEMA IEC body phantoms, and Jaszczak SPECT phantoms. The dual-roller rotation system mixes the radio-nuclide solution while keeping the phantom safely on the bench, minimizing personnel handling time and supporting \u003cstrong\u003eALARA-compliant workflows\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eWhy choose the Pro-NM Automixer?\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cmeta charset=\"utf-8\"\u003e✅ \u003cstrong\u003eReduces radiation exposure\u003c\/strong\u003e – minimizes hands-on time during phantom preparation (ALARA principle)\u003cbr\u003e✅ \u003cstrong\u003eImproved solution homogeneity\u003c\/strong\u003e – critical for uniformity testing and SUV calibration accuracy\u003cbr\u003e✅ \u003cstrong\u003eDual-roller design\u003c\/strong\u003e – rotates the phantom without contacting or damaging the cylinder surface\u003cbr\u003e✅ \u003cstrong\u003eCompatible with standard NM phantoms\u003c\/strong\u003e – Jaszczak (Ø220 mm) and NEMA IEC body phantom (Ø300 mm)\u003cbr\u003e✅ \u003cstrong\u003eAutomatic, hands-free operation\u003c\/strong\u003e – no manual inversion or shaking required\u003cbr\u003e✅ \u003cstrong\u003eQuiet, low-power operation\u003c\/strong\u003e – approximately 10 W consumption\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eTechnical specifications:\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Dimensions: 425 x 220 x 130 mm\u003cbr\u003e✅ Weight: 4 kg\u003cbr\u003e✅ Rotation speed: ~40 rpm (Jaszczak Ø220 mm), ~27 rpm (NEMA IEC Ø300 mm)\u003cbr\u003e✅ Power consumption: ~10 W\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003e✅ Power supply: \u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eplug-in power supply (AC100-240V~50\/60Hz)\u003c\/span\u003e\u003cbr\u003e✅ Typical mixing time: 5–10 minutes\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eCompatible phantoms:\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Pro-NM ACR Performance PET Lid phantom\u003cbr\u003e✅ Pro-NM NEMA IEC body phantom\u003cbr\u003e✅ Other standard cylindrical PET\/SPECT phantoms (Jaszczak Ø220 mm, NEMA Ø300 mm)\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eWhat's included:\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Pro-NM Automixer unit\u003cbr\u003e✅ Power supply\u003cbr\u003e✅ User manual with operating guidelines\u003cbr\u003e✅ Optional: rotation support (sold separately)\u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eStandards compliance:\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ CE marked\u003cbr\u003e✅ Designed for use with cylindrical phantoms requiring homogeneous radioactive solutions\u003cbr\u003e✅ Detailed user manual included\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eBetter mixing. Lower exposure. Faster prep.\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eStreamline your nuclear medicine QA workflow with automated, hands-free phantom preparation.\u003c\/p\u003e\n\u003ch3 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eOrder your Pro-NM Automixer today.\u003c\/strong\u003e\u003c\/h3\u003e","brand":"Diagnomatic","offers":[{"title":"Default Title","offer_id":55645692854612,"sku":null,"price":790.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/0640\/9300\/files\/pro-nm_automixer_460e3019-8368-4c31-9c8d-5b6b9a2e128a.webp?v=1777566881"},{"product_id":"pro-nm-acr-performance-spect-lid","title":"Pro-NM ACR Performance SPECT","description":"\u003ch2\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003eACR-Approved. AAPM Report 177 compliant. Built for SPECT accreditation testing.\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eThree-in-one phantom design for spatial resolution, cold-spot contrast, and tomographic uniformity assessment.\u003c\/strong\u003e\u003cbr\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe Pro-NM ACR Performance SPECT Phantom is a tomographic imaging phantom designed to meet ACR Nuclear Medicine Accreditation Program requirements. It combines three test sections in a single PMMA cylinder: a cold rod insert for spatial resolution assessment (4.8–12.7 mm rods), a uniform section for tomographic uniformity testing, and a set of six solid cold spheres (9.5–31.8 mm) for cold-spot contrast evaluation and assessment of attenuation and scatter correction algorithms.\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eBuilt for the full SPECT QA lifecycle\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eACR accreditation testing\u003c\/strong\u003e – meets ACR Nuclear Medicine Accreditation Program requirements\u003cbr\u003e✅ \u003cstrong\u003eAcceptance testing\u003c\/strong\u003e – post-installation performance verification\u003cbr\u003e✅ \u003cstrong\u003eAnnual medical physicist surveys\u003c\/strong\u003e – aligned with AAPM Report 177 protocols\u003cbr\u003e✅ \u003cstrong\u003eRoutine quality control\u003c\/strong\u003e – uniformity, resolution, and contrast monitoring\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-pre-wrap leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eWhy choose the Pro-NM ACR Performance SPECT Phantom?\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eACR-Approved\u003c\/strong\u003e – meets ACR Nuclear Medicine Accreditation Program requirements\u003cbr\u003e✅ \u003cstrong\u003eAAPM Report 177 compliant\u003c\/strong\u003e – aligned with current US medical physics guidelines for gamma camera, SPECT, and SPECT\/CT systems\u003cbr\u003e✅ \u003cstrong\u003eReferenced in the ACR Nuclear Medicine Quality Control Manual (2024)\u003c\/strong\u003e – documented test protocols included\u003cbr\u003e✅ \u003cstrong\u003eThree test sections in one phantom\u003c\/strong\u003e – spatial resolution, uniformity, and cold-spot contrast\u003cbr\u003e✅ \u003cstrong\u003eStandard ACR rod insert\u003c\/strong\u003e – 4.8, 6.4, 7.9, 9.5, 11.1, and 12.7 mm rods\u003cbr\u003e✅ \u003cstrong\u003eSix solid cold spheres\u003c\/strong\u003e – 9.5–31.8 mm for contrast and attenuation\/scatter correction assessment\u003cbr\u003e✅ \u003cstrong\u003eCE marked\u003c\/strong\u003e – EU regulatory compliance\u003cbr\u003e✅ \u003cstrong\u003eDetailed user manual\u003c\/strong\u003e – step-by-step test execution and results assessment\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2\u003eTechnical specs:\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eMain cylinder (PMMA)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Inside diameter: 209.6 mm (8¼\")\u003cbr\u003e✅ Inside height: 184 mm\u003cbr\u003e✅ Wall thickness: 6.4 mm (¼\")\u003cbr\u003e✅ HU range: 110–135\u003cbr\u003e✅ Volume (empty): 6.35 L\u003cbr\u003e✅ Volume with cold rod insert: 5.55 L\u003cbr\u003e✅ Spheres do not significantly affect volume\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eCold rod insert\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Rod diameters: 4.8, 6.4, 7.9, 9.5, 11.1, 12.7 mm\u003cbr\u003e✅ Rod height: 88 mm\u003cbr\u003e✅ Standard ACR configuration and orientation\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eCold spheres\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Solid sphere diameters: 9.5, 12.7, 15.9, 19.1, 25.4, 31.8 mm\u003cbr\u003e✅ Sphere center height from base plate: 127 mm\u003cbr\u003e✅ Sphere center radius from phantom center: ~60 mm\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2\u003eStandards compliance:\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003e✅ ACR Nuclear Medicine and PET Accreditation Program requirements\u003cbr\u003e✅ AAPM Report No. 177\u003cbr\u003e✅ \u003cmeta charset=\"utf-8\"\u003eReferenced in \u003cem\u003eNuclear Medicine Quality Control Manual\u003c\/em\u003e (ACR, 2024)\u003cbr\u003e✅ CE marked\u003cbr\u003e✅ Comprehensive user manual with step-by-step test execution and evaluation criteria\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eOptimize your phantom preparation workflow\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eTomographic uniformity testing depends on a fully homogeneous radioactive solution (typically Tc-99m). Pair your Pro-NM ACR Performance SPECT lid Phantom with the \u003cstrong\u003ePro-NM Automixer\u003c\/strong\u003e for:\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-pre-wrap leading-[1.7]\"\u003e✅ Hands-free, automated phantom rotation\u003cbr\u003e✅ Reduced personnel radiation exposure (ALARA-compliant workflow)\u003cbr\u003e✅ Consistent, reproducible solution homogeneity\u003cbr\u003e✅ Mixing complete in 5–10 minutes\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003ca href=\"https:\/\/shop.diagnomatic.com\/products\/pro-nm-automixer\" title=\"Pro-NM AutoMixer\" rel=\"noopener\" target=\"_blank\"\u003e→ See the Pro-NM Automixer\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eWhat's included:\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003e✅ Pro-NM ACR Performance SPECT Phantom (cylinder + cold rod insert + six cold spheres)\u003cbr\u003e✅ User manual with test protocols\u003cbr\u003e✅ Optional: heavy-duty carrying case\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eDelivery time:\u003c\/h2\u003e\n\u003cp class=\"p3\"\u003e\u003cspan class=\"s2\"\u003e\u003cb\u003e2–3 weeks\u003c\/b\u003e\u003c\/span\u003e from order confirmation\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eSPECT accreditation testing with documented protocols.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eGet the ACR-approved phantom built to meet the exact requirements of the ACR Nuclear Medicine Accreditation Program.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cstrong\u003eOrder your Pro-NM ACR Performance SPECT Phantom today.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Diagnomatic","offers":[{"title":"Default Title","offer_id":55655526662484,"sku":null,"price":1990.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/0640\/9300\/files\/SPECT_bd83371b-584d-47a8-8b1c-e73fc22743ef.webp?v=1777566859"},{"product_id":"pro-nm-acr-performance-pet-spect-lid","title":"Pro-NM ACR Performance PET + SPECT","description":"\u003ch2\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta charset=\"utf-8\"\u003eACR-Approved. AAPM Report 177 compliant. One phantom for both SPECT and PET accreditation.\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eComplete tomographic QA solution with interchangeable SPECT and PET configurations.\u003c\/strong\u003e\u003cbr\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe Pro-NM ACR Performance Phantom is a dual-configuration tomographic imaging phantom designed to meet ACR Nuclear Medicine and PET Accreditation Program requirements in a single device. By swapping between the included SPECT Lid (with cold spheres) and PET Lid (with refillable cylinders), the phantom covers both accreditation pathways – making it the most cost-effective solution for facilities operating both SPECT and PET systems, or for medical physicists conducting QA across multiple modalities.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eOne phantom. Two ACR accreditation pathways.\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eMost facilities and consulting medical physicists need separate phantoms for SPECT and PET accreditation testing. The Pro-NM ACR Performance Phantom replaces both with a single, modular device:\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eSPECT configuration\u003c\/strong\u003e – install the SPECT Lid with six cold spheres for ACR Nuclear Medicine accreditation testing\u003cbr\u003e✅ \u003cstrong\u003ePET configuration\u003c\/strong\u003e – swap to the PET Lid with refillable cylinders for ACR PET accreditation testing\u003cbr\u003e✅ \u003cstrong\u003eShared cylinder and rod insert\u003c\/strong\u003e – the same main body and cold rod insert serve both modalities\u003cbr\u003e✅ \u003cstrong\u003eLower total cost of ownership\u003c\/strong\u003e – one phantom instead of two\u003cbr\u003e✅ \u003cstrong\u003eSingle inventory item\u003c\/strong\u003e – simplified storage, transport, and documentation\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eIdeal for hybrid SPECT\/PET departments, multi-site QA programs, and consulting medical physicists serving facilities with both modalities.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eSPECT configuration – ACR Nuclear Medicine accreditation\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cmeta charset=\"utf-8\"\u003eIn the SPECT configuration, the main cylinder is fitted with the cold rod insert and a set of six solid cold spheres mounted inside the cylinder, then closed with the SPECT Lid. This setup enables assessment of the three core tomographic parameters required by ACR:\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eSpatial resolution\u003c\/strong\u003e – via cold rod insert (4.8–12.7 mm rods)\u003cbr\u003e✅ \u003cstrong\u003eCold-spot contrast\u003c\/strong\u003e – via six solid cold spheres (9.5–31.8 mm) \u003cmeta charset=\"utf-8\"\u003esuspended inside the cylinder\u003cbr\u003e✅ \u003cstrong\u003eTomographic uniformity\u003c\/strong\u003e – via uniform PMMA section\u003cbr\u003e✅ \u003cstrong\u003eAttenuation and scatter correction\u003c\/strong\u003e – assessment of correction algorithm effectiveness\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003ePET configuration – ACR PET accreditation\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eSwitching to the PET configuration is straightforward: simply replace the SPECT Lid with the PET Lid – a cover with built-in refillable thin-walled cylinders (Esser-style). The cold rod insert and cold spheres remain inside the cylinder, but only the PET Lid cylinders are imaged in the relevant axial plane during PET accreditation testing. The refillable cylinders allow custom hot-to-background activity ratios:\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eSpatial resolution\u003c\/strong\u003e – via the same cold rod insert used in SPECT mode\u003cbr\u003e✅ \u003cstrong\u003eHot and cold lesion contrast\u003c\/strong\u003e – via refillable cylinders built into the PET Lid (8, 12, 16, and 25 mm)\u003cbr\u003e✅ \u003cstrong\u003eSUV uniformity and calibration\u003c\/strong\u003e – via uniform PMMA section (current ACR criteria: background SUV 0.90–1.10)\u003cbr\u003e✅ \u003cstrong\u003eAttenuation reference\u003c\/strong\u003e – via Teflon® cylinder (bone-equivalent)\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe refillable design allows flexible activity ratios for clinical FDG protocols, harmonization studies, and protocol-specific testing.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eWhy choose the Pro-NM ACR Performance Phantom?\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eTwo ACR accreditation pathways in one device\u003c\/strong\u003e – SPECT and PET\u003cbr\u003e✅ \u003cstrong\u003eAAPM Report 177 compliant\u003c\/strong\u003e – aligned with current US medical physics guidelines for gamma camera, SPECT, SPECT\/CT, and PET systems\u003cbr\u003e✅ \u003cstrong\u003eReferenced in ACR Nuclear Medicine QC Manual (2024) and ACR PET QC Manual (2025)\u003c\/strong\u003e – documented test protocols included\u003cbr\u003e✅ \u003cstrong\u003eStandard ACR rod insert and cold sphere set\u003c\/strong\u003e – matches established Jaszczak deluxe configuration\u003cbr\u003e✅ \u003cstrong\u003eRefillable PET cylinders\u003c\/strong\u003e – flexible activity ratios for clinical and research protocols\u003cbr\u003e✅ \u003cstrong\u003eCost-effective solution\u003c\/strong\u003e – one phantom instead of two\u003cbr\u003e✅ \u003cstrong\u003eCE marked\u003c\/strong\u003e – EU regulatory compliance\u003cbr\u003e✅ \u003cstrong\u003eDetailed user manual\u003c\/strong\u003e – step-by-step test execution and results assessment for both configurations\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2\u003eTechnical specs:\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eMain cylinder (PMMA)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Inside diameter: 209.6 mm (8¼\")\u003cbr\u003e✅ Inside height: 184 mm\u003cbr\u003e✅ Wall thickness: 6.4 mm (¼\")\u003cbr\u003e✅ HU range: 110–135\u003cbr\u003e✅ Volume (empty): 6.35 L\u003cbr\u003e✅ Volume with cold rod insert: 5.55 L\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eCold rod insert\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Rod diameters: 4.8, 6.4, 7.9, 9.5, 11.1, 12.7 mm\u003cbr\u003e✅ Rod height: 88 mm\u003cbr\u003e✅ Standard ACR configuration and orientation\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eCold spheres\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Solid sphere diameters: 9.5, 12.7, 15.9, 19.1, 25.4, 31.8 mm\u003cbr\u003e✅ Sphere center height from base plate: 127 mm\u003cbr\u003e✅ Sphere center radius from phantom center: ~60 mm\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003ePET Lid\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Refillable thin-walled cylinders: 8 mm (1.9 mL), 12 mm (4.3 mL), 16 mm (7.7 mL), 25 mm (18.7 mL ×3)\u003cbr\u003e✅ Air \u0026amp; water cylinders: 25 mm internal diameter, 29.4 mm external, 38.1 mm height\u003cbr\u003e✅ Teflon® cylinder: 25 mm diameter, 38.1 mm height (bone-equivalent reference)\u003cbr\u003e✅ Cylinder placement radius: ~67 mm (134 mm diameter)\u003cbr\u003e✅ Volume with PET Lid (no insert): 6.2 L\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2\u003eStandards compliance:\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003e✅ ACR Nuclear Medicine Accreditation Program requirements\u003cbr\u003e✅ ACR PET Accreditation Program requirements\u003cbr\u003e✅ AAPM Report No. 177\u003cbr\u003e✅ Referenced in \u003cem\u003eNuclear Medicine Quality Control Manual\u003c\/em\u003e (ACR, 2024)\u003cbr\u003e✅ Referenced in \u003cem\u003ePositron Emission Tomography Quality Control Manual\u003c\/em\u003e (ACR, 2025)\u003cbr\u003e✅ CE marked\u003cbr\u003e✅ Comprehensive user manual with step-by-step test execution and evaluation criteria for both configurations\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eOptimize your phantom preparation workflow\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eOptimize your phantom preparation workflow\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eBoth SPECT uniformity testing (Tc-99m) and PET background SUV calibration (F-18, current ACR criteria 0.90–1.10) depend on a fully homogeneous radioactive solution. Pair your Pro-NM ACR Performance Phantom with the \u003cstrong\u003ePro-NM Automixer\u003c\/strong\u003e for:\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-pre-wrap leading-[1.7]\"\u003e✅ Hands-free, automated phantom rotation\u003cbr\u003e✅ Reduced personnel radiation exposure (\u003cstrong\u003eALARA-compliant workflow\u003c\/strong\u003e)\u003cbr\u003e✅ Consistent, reproducible solution homogeneity for both SPECT and PET protocols ✅ Mixing complete in 5–10 minutes\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003ca href=\"https:\/\/shop.diagnomatic.com\/products\/pro-nm-automixer\" title=\"Pro-NM AutoMixer\" rel=\"noopener\" target=\"_blank\"\u003e→ See the Pro-NM Automixer\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eWhat's included:\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e✅ Pro-NM ACR Performance Phantom main cylinder\u003cbr\u003e✅ Cold rod insert (standard ACR configuration)\u003cbr\u003e✅ SPECT Lid (cylinder cover)\u003cbr\u003e✅ Set of six solid cold spheres with mounting base\u003cbr\u003e✅ PET Lid with built-in refillable cylinders (Esser-style)\u003cbr\u003e✅ User manual with test protocols for both configurations\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eDelivery time:\u003c\/h2\u003e\n\u003cp class=\"p3\"\u003e\u003cspan class=\"s2\"\u003e\u003cb\u003e2–3 weeks\u003c\/b\u003e\u003c\/span\u003e from order confirmation\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eSPECT and PET accreditation testing in one phantom.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eGet the ACR-approved phantom built to meet the exact requirements of both the ACR Nuclear Medicine and PET Accreditation Programs.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cstrong\u003eOrder your Pro-NM ACR Performance Phantom today.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Diagnomatic","offers":[{"title":"Default Title","offer_id":55656408580436,"sku":null,"price":3200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/0640\/9300\/files\/pro-nm_acr_performance_pet_e4cc03a2-a3aa-44f9-82c3-2638e566166b.webp?v=1777566828"},{"product_id":"pro-nm-acr-performance-small","title":"Pro-NM ACR Performance Small","description":"\u003ch2\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta charset=\"utf-8\"\u003eACR-Approved. Built for small field-of-view SPECT and PET systems.\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eCompact tomographic phantom for dedicated cardiac, head, and preclinical imaging systems where the standard ACR phantom won't fit.\u003c\/strong\u003e\u003cbr\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe Pro-NM ACR Performance Small Phantom is a compact tomographic imaging phantom designed for performance evaluation of small field-of-view (FOV) SPECT and PET systems – including dedicated cardiac SPECT cameras, dedicated head SPECT\/brain imaging units, and compact PET scanners that cannot accommodate the standard 209.6 mm Jaszczak deluxe phantom. With a 139.7 mm (5½\") inside diameter, the phantom fits the bore of small-FOV systems while maintaining ACR Nuclear Medicine Accreditation Program compliance for tomographic resolution, uniformity, and contrast testing.\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eDesigned for systems where the standard phantom won't fit\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eMany modern dedicated SPECT and compact PET systems – such as cardiac-dedicated cameras (D-SPECT, cardiac CZT systems), brain-dedicated systems, and small-bore preclinical scanners – have field-of-view dimensions too small for the standard Jaszczak deluxe phantom (Ø209.6 mm). The Pro-NM ACR Performance Small Phantom is the ACR-compliant solution for these systems:\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eCompact 139.7 mm (5½\") cylinder\u003c\/strong\u003e – fits small-FOV detector geometries\u003cbr\u003e✅ \u003cstrong\u003eFull ACR test capability\u003c\/strong\u003e – cold rods, solid spheres, and uniform region in one phantom\u003cbr\u003e✅ \u003cstrong\u003eApproved for ACR accreditation\u003c\/strong\u003e of small-FOV systems where indicated by ACR protocols\u003cbr\u003e✅ \u003cstrong\u003eSame test methodology\u003c\/strong\u003e as the standard Pro-NM phantom – familiar workflow for medical physicists\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-pre-wrap leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eWhat you can test with the Pro-NM Small Phantom\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eCore ACR tomographic parameters:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eSpatial resolution\u003c\/strong\u003e – via cold rod insert (4.8–12.7 mm rods)\u003cbr\u003e✅ \u003cstrong\u003eCold-spot contrast\u003c\/strong\u003e – via six solid cold spheres (6.4–25.4 mm)\u003cbr\u003e✅ \u003cstrong\u003eTomographic uniformity\u003c\/strong\u003e – via uniform PMMA section\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eExtended QA applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Collimator and reconstruction parameter testing\u003cbr\u003e✅ Imaging artifact evaluation\u003cbr\u003e✅ Center-of-rotation (COR) error assessment\u003cbr\u003e✅ Non-uniformity artifact identification\u003cbr\u003e✅ Impact of rotation radius on spatial resolution\u003cbr\u003e✅ Effect of reconstruction filters on spatial resolution\u003cbr\u003e✅ Effectiveness of attenuation and scatter correction algorithms\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eWhy choose the Pro-NM ACR Performance Small Phantom?\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eDesigned for small-FOV systems\u003c\/strong\u003e – fits dedicated cardiac, brain, and compact PET scanners\u003cbr\u003e✅ \u003cstrong\u003eACR-compliant\u003c\/strong\u003e – meets ACR Nuclear Medicine Accreditation Program requirements for small-FOV testing\u003cbr\u003e✅ \u003cstrong\u003eReferenced in the ACR Nuclear Medicine Quality Control Manual (2024)\u003c\/strong\u003e – documented test protocols included\u003cbr\u003e✅ \u003cstrong\u003eAll three core test sections\u003c\/strong\u003e – cold rods, solid cold spheres, and uniform region\u003cbr\u003e✅ \u003cstrong\u003eVersatile for routine QA\u003c\/strong\u003e – COR assessment, collimator testing, reconstruction parameter studies\u003cbr\u003e✅ \u003cstrong\u003eCE marked\u003c\/strong\u003e – EU regulatory compliance\u003cbr\u003e✅ \u003cstrong\u003eDetailed user manual\u003c\/strong\u003e – step-by-step test execution and results assessment\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2\u003eTechnical specs:\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eMain cylinder (PMMA)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Inside diameter: 139.7 mm (5½\")\u003cbr\u003e✅ Inside height: 150 mm\u003cbr\u003e✅ Wall thickness: 6.4 mm (¼\")\u003cbr\u003e✅ Outside diameter: 152.2–152.5 mm\u003cbr\u003e✅ Overall length: 170 mm\u003cbr\u003e✅ HU range: 110–135\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eCold rod insert (PMMA, HU 110–135)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cem\u003e\u003c\/em\u003e✅ Rod diameters: 4.8 mm (×21), 6.4 mm (×13), 7.9 mm (×8), 9.5 mm (×6), 11.1 mm (×3), 12.7 mm (×3)\u003cbr\u003e✅ Rod height: 40 mm\u003cbr\u003e✅ Standard ACR configuration and orientation\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eCold spheres\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Solid sphere diameters: 6.4, 9.5, 12.7, 15.9, 19.1, 25.4 mm\u003cbr\u003e✅ Sphere center height from base plate: 78 mm\u003cbr\u003e✅ Sphere center radius from phantom center: 50 mm\u003cbr\u003e✅ Angular spacing: 60°\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2\u003eStandards compliance:\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e✅ ACR Nuclear Medicine Accreditation Program requirements (small-FOV testing)\u003cbr\u003e✅ Referenced in \u003cem\u003eNuclear Medicine Quality Control Manual\u003c\/em\u003e (ACR, 2024)\u003cbr\u003e✅ CE marked\u003cbr\u003e✅ Comprehensive user manual with step-by-step test execution and evaluation criteria\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eWhat's included:\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e✅ Pro-NM ACR Performance Small Phantom main cylinder\u003cbr\u003e✅ Cold rod insert (standard ACR configuration)\u003cbr\u003e✅ Set of six solid cold spheres with mounting base\u003cbr\u003e✅ User manual with test protocols\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eDelivery time:\u003c\/h2\u003e\n\u003cp class=\"p3\"\u003e\u003cspan class=\"s2\"\u003e\u003cb\u003e2–3 weeks\u003c\/b\u003e\u003c\/span\u003e from order confirmation\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eACR-compliant QA for small-FOV SPECT and PET systems.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eGet the ACR-approved phantom designed specifically for dedicated cardiac, brain, and compact tomographic imaging systems.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cstrong\u003eOrder your Pro-NM ACR Performance Small Phantom today.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Diagnomatic","offers":[{"title":"Default Title","offer_id":55660785008980,"sku":null,"price":1700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/0640\/9300\/files\/ACR_performance_small_43e8f28f-8561-43da-bc77-70c43eace025.webp?v=1777566793"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/0640\/9300\/collections\/NukMed.webp?v=1777299987","url":"https:\/\/shop.diagnomatic.com\/collections\/nuclear-medicine.oembed","provider":"Diagnomatic","version":"1.0","type":"link"}