{"product_id":"pro-nm-acr-performance-pet-spect-lid","title":"Pro-NM ACR Performance PET + SPECT","description":"\u003ch2\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta charset=\"utf-8\"\u003eACR-Approved. AAPM Report 177 compliant. One phantom for both SPECT and PET accreditation.\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eComplete tomographic QA solution with interchangeable SPECT and PET configurations.\u003c\/strong\u003e\u003cbr\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe Pro-NM ACR Performance Phantom is a dual-configuration tomographic imaging phantom designed to meet ACR Nuclear Medicine and PET Accreditation Program requirements in a single device. By swapping between the included SPECT Lid (with cold spheres) and PET Lid (with refillable cylinders), the phantom covers both accreditation pathways – making it the most cost-effective solution for facilities operating both SPECT and PET systems, or for medical physicists conducting QA across multiple modalities.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eOne phantom. Two ACR accreditation pathways.\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eMost facilities and consulting medical physicists need separate phantoms for SPECT and PET accreditation testing. The Pro-NM ACR Performance Phantom replaces both with a single, modular device:\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eSPECT configuration\u003c\/strong\u003e – install the SPECT Lid with six cold spheres for ACR Nuclear Medicine accreditation testing\u003cbr\u003e✅ \u003cstrong\u003ePET configuration\u003c\/strong\u003e – swap to the PET Lid with refillable cylinders for ACR PET accreditation testing\u003cbr\u003e✅ \u003cstrong\u003eShared cylinder and rod insert\u003c\/strong\u003e – the same main body and cold rod insert serve both modalities\u003cbr\u003e✅ \u003cstrong\u003eLower total cost of ownership\u003c\/strong\u003e – one phantom instead of two\u003cbr\u003e✅ \u003cstrong\u003eSingle inventory item\u003c\/strong\u003e – simplified storage, transport, and documentation\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eIdeal for hybrid SPECT\/PET departments, multi-site QA programs, and consulting medical physicists serving facilities with both modalities.\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eSPECT configuration – ACR Nuclear Medicine accreditation\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cmeta charset=\"utf-8\"\u003eIn the SPECT configuration, the main cylinder is fitted with the cold rod insert and a set of six solid cold spheres mounted inside the cylinder, then closed with the SPECT Lid. This setup enables assessment of the three core tomographic parameters required by ACR:\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eSpatial resolution\u003c\/strong\u003e – via cold rod insert (4.8–12.7 mm rods)\u003cbr\u003e✅ \u003cstrong\u003eCold-spot contrast\u003c\/strong\u003e – via six solid cold spheres (9.5–31.8 mm) \u003cmeta charset=\"utf-8\"\u003esuspended inside the cylinder\u003cbr\u003e✅ \u003cstrong\u003eTomographic uniformity\u003c\/strong\u003e – via uniform PMMA section\u003cbr\u003e✅ \u003cstrong\u003eAttenuation and scatter correction\u003c\/strong\u003e – assessment of correction algorithm effectiveness\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003ePET configuration – ACR PET accreditation\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eSwitching to the PET configuration is straightforward: simply replace the SPECT Lid with the PET Lid – a cover with built-in refillable thin-walled cylinders (Esser-style). The cold rod insert and cold spheres remain inside the cylinder, but only the PET Lid cylinders are imaged in the relevant axial plane during PET accreditation testing. The refillable cylinders allow custom hot-to-background activity ratios:\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eSpatial resolution\u003c\/strong\u003e – via the same cold rod insert used in SPECT mode\u003cbr\u003e✅ \u003cstrong\u003eHot and cold lesion contrast\u003c\/strong\u003e – via refillable cylinders built into the PET Lid (8, 12, 16, and 25 mm)\u003cbr\u003e✅ \u003cstrong\u003eSUV uniformity and calibration\u003c\/strong\u003e – via uniform PMMA section (current ACR criteria: background SUV 0.90–1.10)\u003cbr\u003e✅ \u003cstrong\u003eAttenuation reference\u003c\/strong\u003e – via Teflon® cylinder (bone-equivalent)\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eThe refillable design allows flexible activity ratios for clinical FDG protocols, harmonization studies, and protocol-specific testing.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eWhy choose the Pro-NM ACR Performance Phantom?\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eTwo ACR accreditation pathways in one device\u003c\/strong\u003e – SPECT and PET\u003cbr\u003e✅ \u003cstrong\u003eAAPM Report 177 compliant\u003c\/strong\u003e – aligned with current US medical physics guidelines for gamma camera, SPECT, SPECT\/CT, and PET systems\u003cbr\u003e✅ \u003cstrong\u003eReferenced in ACR Nuclear Medicine QC Manual (2024) and ACR PET QC Manual (2025)\u003c\/strong\u003e – documented test protocols included\u003cbr\u003e✅ \u003cstrong\u003eStandard ACR rod insert and cold sphere set\u003c\/strong\u003e – matches established Jaszczak deluxe configuration\u003cbr\u003e✅ \u003cstrong\u003eRefillable PET cylinders\u003c\/strong\u003e – flexible activity ratios for clinical and research protocols\u003cbr\u003e✅ \u003cstrong\u003eCost-effective solution\u003c\/strong\u003e – one phantom instead of two\u003cbr\u003e✅ \u003cstrong\u003eCE marked\u003c\/strong\u003e – EU regulatory compliance\u003cbr\u003e✅ \u003cstrong\u003eDetailed user manual\u003c\/strong\u003e – step-by-step test execution and results assessment for both configurations\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2\u003eTechnical specs:\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eMain cylinder (PMMA)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Inside diameter: 209.6 mm (8¼\")\u003cbr\u003e✅ Inside height: 184 mm\u003cbr\u003e✅ Wall thickness: 6.4 mm (¼\")\u003cbr\u003e✅ HU range: 110–135\u003cbr\u003e✅ Volume (empty): 6.35 L\u003cbr\u003e✅ Volume with cold rod insert: 5.55 L\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eCold rod insert\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Rod diameters: 4.8, 6.4, 7.9, 9.5, 11.1, 12.7 mm\u003cbr\u003e✅ Rod height: 88 mm\u003cbr\u003e✅ Standard ACR configuration and orientation\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eCold spheres\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Solid sphere diameters: 9.5, 12.7, 15.9, 19.1, 25.4, 31.8 mm\u003cbr\u003e✅ Sphere center height from base plate: 127 mm\u003cbr\u003e✅ Sphere center radius from phantom center: ~60 mm\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003ePET Lid\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Refillable thin-walled cylinders: 8 mm (1.9 mL), 12 mm (4.3 mL), 16 mm (7.7 mL), 25 mm (18.7 mL ×3)\u003cbr\u003e✅ Air \u0026amp; water cylinders: 25 mm internal diameter, 29.4 mm external, 38.1 mm height\u003cbr\u003e✅ Teflon® cylinder: 25 mm diameter, 38.1 mm height (bone-equivalent reference)\u003cbr\u003e✅ Cylinder placement radius: ~67 mm (134 mm diameter)\u003cbr\u003e✅ Volume with PET Lid (no insert): 6.2 L\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2\u003eStandards compliance:\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003e✅ ACR Nuclear Medicine Accreditation Program requirements\u003cbr\u003e✅ ACR PET Accreditation Program requirements\u003cbr\u003e✅ AAPM Report No. 177\u003cbr\u003e✅ Referenced in \u003cem\u003eNuclear Medicine Quality Control Manual\u003c\/em\u003e (ACR, 2024)\u003cbr\u003e✅ Referenced in \u003cem\u003ePositron Emission Tomography Quality Control Manual\u003c\/em\u003e (ACR, 2025)\u003cbr\u003e✅ CE marked\u003cbr\u003e✅ Comprehensive user manual with step-by-step test execution and evaluation criteria for both configurations\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eOptimize your phantom preparation workflow\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eOptimize your phantom preparation workflow\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eBoth SPECT uniformity testing (Tc-99m) and PET background SUV calibration (F-18, current ACR criteria 0.90–1.10) depend on a fully homogeneous radioactive solution. Pair your Pro-NM ACR Performance Phantom with the \u003cstrong\u003ePro-NM Automixer\u003c\/strong\u003e for:\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-pre-wrap leading-[1.7]\"\u003e✅ Hands-free, automated phantom rotation\u003cbr\u003e✅ Reduced personnel radiation exposure (\u003cstrong\u003eALARA-compliant workflow\u003c\/strong\u003e)\u003cbr\u003e✅ Consistent, reproducible solution homogeneity for both SPECT and PET protocols ✅ Mixing complete in 5–10 minutes\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003ca href=\"https:\/\/shop.diagnomatic.com\/products\/pro-nm-automixer\" title=\"Pro-NM AutoMixer\" rel=\"noopener\" target=\"_blank\"\u003e→ See the Pro-NM Automixer\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eWhat's included:\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e✅ Pro-NM ACR Performance Phantom main cylinder\u003cbr\u003e✅ Cold rod insert (standard ACR configuration)\u003cbr\u003e✅ SPECT Lid (cylinder cover)\u003cbr\u003e✅ Set of six solid cold spheres with mounting base\u003cbr\u003e✅ PET Lid with built-in refillable cylinders (Esser-style)\u003cbr\u003e✅ User manual with test protocols for both configurations\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eDelivery time:\u003c\/h2\u003e\n\u003cp class=\"p3\"\u003e\u003cspan class=\"s2\"\u003e\u003cb\u003e2–3 weeks\u003c\/b\u003e\u003c\/span\u003e from order confirmation\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eSPECT and PET accreditation testing in one phantom.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eGet the ACR-approved phantom built to meet the exact requirements of both the ACR Nuclear Medicine and PET Accreditation Programs.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cstrong\u003eOrder your Pro-NM ACR Performance Phantom today.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Diagnomatic","offers":[{"title":"Default Title","offer_id":55656408580436,"sku":null,"price":3200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/0640\/9300\/files\/pro-nm_acr_performance_pet_e4cc03a2-a3aa-44f9-82c3-2638e566166b.webp?v=1777566828","url":"https:\/\/shop.diagnomatic.com\/products\/pro-nm-acr-performance-pet-spect-lid","provider":"Diagnomatic","version":"1.0","type":"link"}