{"product_id":"pro-nm-acr-performance-small","title":"Pro-NM ACR Performance Small","description":"\u003ch2\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cmeta charset=\"utf-8\"\u003eACR-Approved. Built for small field-of-view SPECT and PET systems.\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eCompact tomographic phantom for dedicated cardiac, head, and preclinical imaging systems where the standard ACR phantom won't fit.\u003c\/strong\u003e\u003cbr\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe Pro-NM ACR Performance Small Phantom is a compact tomographic imaging phantom designed for performance evaluation of small field-of-view (FOV) SPECT and PET systems – including dedicated cardiac SPECT cameras, dedicated head SPECT\/brain imaging units, and compact PET scanners that cannot accommodate the standard 209.6 mm Jaszczak deluxe phantom. With a 139.7 mm (5½\") inside diameter, the phantom fits the bore of small-FOV systems while maintaining ACR Nuclear Medicine Accreditation Program compliance for tomographic resolution, uniformity, and contrast testing.\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eDesigned for systems where the standard phantom won't fit\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eMany modern dedicated SPECT and compact PET systems – such as cardiac-dedicated cameras (D-SPECT, cardiac CZT systems), brain-dedicated systems, and small-bore preclinical scanners – have field-of-view dimensions too small for the standard Jaszczak deluxe phantom (Ø209.6 mm). The Pro-NM ACR Performance Small Phantom is the ACR-compliant solution for these systems:\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eCompact 139.7 mm (5½\") cylinder\u003c\/strong\u003e – fits small-FOV detector geometries\u003cbr\u003e✅ \u003cstrong\u003eFull ACR test capability\u003c\/strong\u003e – cold rods, solid spheres, and uniform region in one phantom\u003cbr\u003e✅ \u003cstrong\u003eApproved for ACR accreditation\u003c\/strong\u003e of small-FOV systems where indicated by ACR protocols\u003cbr\u003e✅ \u003cstrong\u003eSame test methodology\u003c\/strong\u003e as the standard Pro-NM phantom – familiar workflow for medical physicists\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-pre-wrap leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eWhat you can test with the Pro-NM Small Phantom\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eCore ACR tomographic parameters:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eSpatial resolution\u003c\/strong\u003e – via cold rod insert (4.8–12.7 mm rods)\u003cbr\u003e✅ \u003cstrong\u003eCold-spot contrast\u003c\/strong\u003e – via six solid cold spheres (6.4–25.4 mm)\u003cbr\u003e✅ \u003cstrong\u003eTomographic uniformity\u003c\/strong\u003e – via uniform PMMA section\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eExtended QA applications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Collimator and reconstruction parameter testing\u003cbr\u003e✅ Imaging artifact evaluation\u003cbr\u003e✅ Center-of-rotation (COR) error assessment\u003cbr\u003e✅ Non-uniformity artifact identification\u003cbr\u003e✅ Impact of rotation radius on spatial resolution\u003cbr\u003e✅ Effect of reconstruction filters on spatial resolution\u003cbr\u003e✅ Effectiveness of attenuation and scatter correction algorithms\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eWhy choose the Pro-NM ACR Performance Small Phantom?\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eDesigned for small-FOV systems\u003c\/strong\u003e – fits dedicated cardiac, brain, and compact PET scanners\u003cbr\u003e✅ \u003cstrong\u003eACR-compliant\u003c\/strong\u003e – meets ACR Nuclear Medicine Accreditation Program requirements for small-FOV testing\u003cbr\u003e✅ \u003cstrong\u003eReferenced in the ACR Nuclear Medicine Quality Control Manual (2024)\u003c\/strong\u003e – documented test protocols included\u003cbr\u003e✅ \u003cstrong\u003eAll three core test sections\u003c\/strong\u003e – cold rods, solid cold spheres, and uniform region\u003cbr\u003e✅ \u003cstrong\u003eVersatile for routine QA\u003c\/strong\u003e – COR assessment, collimator testing, reconstruction parameter studies\u003cbr\u003e✅ \u003cstrong\u003eCE marked\u003c\/strong\u003e – EU regulatory compliance\u003cbr\u003e✅ \u003cstrong\u003eDetailed user manual\u003c\/strong\u003e – step-by-step test execution and results assessment\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2\u003eTechnical specs:\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eMain cylinder (PMMA)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Inside diameter: 139.7 mm (5½\")\u003cbr\u003e✅ Inside height: 150 mm\u003cbr\u003e✅ Wall thickness: 6.4 mm (¼\")\u003cbr\u003e✅ Outside diameter: 152.2–152.5 mm\u003cbr\u003e✅ Overall length: 170 mm\u003cbr\u003e✅ HU range: 110–135\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eCold rod insert (PMMA, HU 110–135)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cem\u003e\u003c\/em\u003e✅ Rod diameters: 4.8 mm (×21), 6.4 mm (×13), 7.9 mm (×8), 9.5 mm (×6), 11.1 mm (×3), 12.7 mm (×3)\u003cbr\u003e✅ Rod height: 40 mm\u003cbr\u003e✅ Standard ACR configuration and orientation\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eCold spheres\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Solid sphere diameters: 6.4, 9.5, 12.7, 15.9, 19.1, 25.4 mm\u003cbr\u003e✅ Sphere center height from base plate: 78 mm\u003cbr\u003e✅ Sphere center radius from phantom center: 50 mm\u003cbr\u003e✅ Angular spacing: 60°\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2\u003eStandards compliance:\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e✅ ACR Nuclear Medicine Accreditation Program requirements (small-FOV testing)\u003cbr\u003e✅ Referenced in \u003cem\u003eNuclear Medicine Quality Control Manual\u003c\/em\u003e (ACR, 2024)\u003cbr\u003e✅ CE marked\u003cbr\u003e✅ Comprehensive user manual with step-by-step test execution and evaluation criteria\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eWhat's included:\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e✅ Pro-NM ACR Performance Small Phantom main cylinder\u003cbr\u003e✅ Cold rod insert (standard ACR configuration)\u003cbr\u003e✅ Set of six solid cold spheres with mounting base\u003cbr\u003e✅ User manual with test protocols\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eDelivery time:\u003c\/h2\u003e\n\u003cp class=\"p3\"\u003e\u003cspan class=\"s2\"\u003e\u003cb\u003e2–3 weeks\u003c\/b\u003e\u003c\/span\u003e from order confirmation\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eACR-compliant QA for small-FOV SPECT and PET systems.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eGet the ACR-approved phantom designed specifically for dedicated cardiac, brain, and compact tomographic imaging systems.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cstrong\u003eOrder your Pro-NM ACR Performance Small Phantom today.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Diagnomatic","offers":[{"title":"Default Title","offer_id":55660785008980,"sku":null,"price":1700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/0640\/9300\/files\/ACR_performance_small_43e8f28f-8561-43da-bc77-70c43eace025.webp?v=1777566793","url":"https:\/\/shop.diagnomatic.com\/products\/pro-nm-acr-performance-small","provider":"Diagnomatic","version":"1.0","type":"link"}