{"product_id":"pro-nm-acr-performance-spect-lid","title":"Pro-NM ACR Performance SPECT","description":"\u003ch2\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cmeta charset=\"utf-8\"\u003eACR-Approved. AAPM Report 177 compliant. Built for SPECT accreditation testing.\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eThree-in-one phantom design for spatial resolution, cold-spot contrast, and tomographic uniformity assessment.\u003c\/strong\u003e\u003cbr\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eThe Pro-NM ACR Performance SPECT Phantom is a tomographic imaging phantom designed to meet ACR Nuclear Medicine Accreditation Program requirements. It combines three test sections in a single PMMA cylinder: a cold rod insert for spatial resolution assessment (4.8–12.7 mm rods), a uniform section for tomographic uniformity testing, and a set of six solid cold spheres (9.5–31.8 mm) for cold-spot contrast evaluation and assessment of attenuation and scatter correction algorithms.\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eBuilt for the full SPECT QA lifecycle\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eACR accreditation testing\u003c\/strong\u003e – meets ACR Nuclear Medicine Accreditation Program requirements\u003cbr\u003e✅ \u003cstrong\u003eAcceptance testing\u003c\/strong\u003e – post-installation performance verification\u003cbr\u003e✅ \u003cstrong\u003eAnnual medical physicist surveys\u003c\/strong\u003e – aligned with AAPM Report 177 protocols\u003cbr\u003e✅ \u003cstrong\u003eRoutine quality control\u003c\/strong\u003e – uniformity, resolution, and contrast monitoring\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-pre-wrap leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eWhy choose the Pro-NM ACR Performance SPECT Phantom?\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ \u003cstrong\u003eACR-Approved\u003c\/strong\u003e – meets ACR Nuclear Medicine Accreditation Program requirements\u003cbr\u003e✅ \u003cstrong\u003eAAPM Report 177 compliant\u003c\/strong\u003e – aligned with current US medical physics guidelines for gamma camera, SPECT, and SPECT\/CT systems\u003cbr\u003e✅ \u003cstrong\u003eReferenced in the ACR Nuclear Medicine Quality Control Manual (2024)\u003c\/strong\u003e – documented test protocols included\u003cbr\u003e✅ \u003cstrong\u003eThree test sections in one phantom\u003c\/strong\u003e – spatial resolution, uniformity, and cold-spot contrast\u003cbr\u003e✅ \u003cstrong\u003eStandard ACR rod insert\u003c\/strong\u003e – 4.8, 6.4, 7.9, 9.5, 11.1, and 12.7 mm rods\u003cbr\u003e✅ \u003cstrong\u003eSix solid cold spheres\u003c\/strong\u003e – 9.5–31.8 mm for contrast and attenuation\/scatter correction assessment\u003cbr\u003e✅ \u003cstrong\u003eCE marked\u003c\/strong\u003e – EU regulatory compliance\u003cbr\u003e✅ \u003cstrong\u003eDetailed user manual\u003c\/strong\u003e – step-by-step test execution and results assessment\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003ch2\u003eTechnical specs:\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eMain cylinder (PMMA)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Inside diameter: 209.6 mm (8¼\")\u003cbr\u003e✅ Inside height: 184 mm\u003cbr\u003e✅ Wall thickness: 6.4 mm (¼\")\u003cbr\u003e✅ HU range: 110–135\u003cbr\u003e✅ Volume (empty): 6.35 L\u003cbr\u003e✅ Volume with cold rod insert: 5.55 L\u003cbr\u003e✅ Spheres do not significantly affect volume\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eCold rod insert\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Rod diameters: 4.8, 6.4, 7.9, 9.5, 11.1, 12.7 mm\u003cbr\u003e✅ Rod height: 88 mm\u003cbr\u003e✅ Standard ACR configuration and orientation\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eCold spheres\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e✅ Solid sphere diameters: 9.5, 12.7, 15.9, 19.1, 25.4, 31.8 mm\u003cbr\u003e✅ Sphere center height from base plate: 127 mm\u003cbr\u003e✅ Sphere center radius from phantom center: ~60 mm\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e \u003c\/p\u003e\n\u003ch2\u003eStandards compliance:\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003e✅ ACR Nuclear Medicine and PET Accreditation Program requirements\u003cbr\u003e✅ AAPM Report No. 177\u003cbr\u003e✅ \u003cmeta charset=\"utf-8\"\u003eReferenced in \u003cem\u003eNuclear Medicine Quality Control Manual\u003c\/em\u003e (ACR, 2024)\u003cbr\u003e✅ CE marked\u003cbr\u003e✅ Comprehensive user manual with step-by-step test execution and evaluation criteria\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eOptimize your phantom preparation workflow\u003c\/h2\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003eTomographic uniformity testing depends on a fully homogeneous radioactive solution (typically Tc-99m). Pair your Pro-NM ACR Performance SPECT lid Phantom with the \u003cstrong\u003ePro-NM Automixer\u003c\/strong\u003e for:\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-pre-wrap leading-[1.7]\"\u003e✅ Hands-free, automated phantom rotation\u003cbr\u003e✅ Reduced personnel radiation exposure (ALARA-compliant workflow)\u003cbr\u003e✅ Consistent, reproducible solution homogeneity\u003cbr\u003e✅ Mixing complete in 5–10 minutes\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003ca href=\"https:\/\/shop.diagnomatic.com\/products\/pro-nm-automixer\" title=\"Pro-NM AutoMixer\" rel=\"noopener\" target=\"_blank\"\u003e→ See the Pro-NM Automixer\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eWhat's included:\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e\u003cmeta charset=\"utf-8\"\u003e✅ Pro-NM ACR Performance SPECT Phantom (cylinder + cold rod insert + six cold spheres)\u003cbr\u003e✅ User manual with test protocols\u003cbr\u003e✅ Optional: heavy-duty carrying case\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eDelivery time:\u003c\/h2\u003e\n\u003cp class=\"p3\"\u003e\u003cspan class=\"s2\"\u003e\u003cb\u003e2–3 weeks\u003c\/b\u003e\u003c\/span\u003e from order confirmation\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp class=\"font-claude-response-body break-words whitespace-normal leading-[1.7]\"\u003e\u003cstrong\u003eSPECT accreditation testing with documented protocols.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003eGet the ACR-approved phantom built to meet the exact requirements of the ACR Nuclear Medicine Accreditation Program.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003e\u003cstrong\u003eOrder your Pro-NM ACR Performance SPECT Phantom today.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Diagnomatic","offers":[{"title":"Default Title","offer_id":55655526662484,"sku":null,"price":1990.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0725\/0640\/9300\/files\/SPECT_bd83371b-584d-47a8-8b1c-e73fc22743ef.webp?v=1777566859","url":"https:\/\/shop.diagnomatic.com\/products\/pro-nm-acr-performance-spect-lid","provider":"Diagnomatic","version":"1.0","type":"link"}