Diagnomatic
Pro-MAM ACR
Pro-MAM ACR
Couldn't load pickup availability
ACR-Approved. Clinically relevant. Designed for confidence.
Ensure your mammographic system is ready for ACR accreditation and daily quality control with the Pro-MAM Accreditation Phantom – a powerful tool for verifying your system’s ability to detect the smallest, most critical breast structures.
From calcifications and fibrous strands to tumor-like masses, the Pro-MAM Phantom simulates real clinical scenarios in a highly reproducible and standardized way, so you can test with confidence and meet accreditation requirements reliably.
What if ACR accreditation could be faster, simpler, and fully documented?
That’s exactly what Diagnomatic is built to deliver. Our QA automation platform takes the complexity out of the process so you can focus on what really matters, your patients.

With Diagnomatic, you can:
✅ Complete QA evaluations automatically – no manual measurements
✅ Instantly generate reports compliant with ACR Mammography Accreditation Program and IEC 61223-3-2
✅ Keep all results securely stored online and accessible anytime
✅ Reduce documentation time, minimize human error, and maintain consistent compliance records
Diagnomatic works seamlessly with the Pro-MAM Accreditation phantom, giving you everything you need to approach accreditation with confidence.
👉 Buyers of the Pro-MAM Accreditation phantom get 2 months of Diagnomatic access free, so you can streamline reporting and compliance from day one.
Why choose the Pro-MAM Accreditation Phantom?
✅ ACR-Approved & CE Certified – full compliance with accreditation standards
✅ Clinically relevant structures – mimics calcifications, ducts, and lesions
✅ Accurate, repeatable results – assess image quality and system performance in one step
✅ Comfortable, protective carrying case included
✅ Can be customized to meet your specifications
Simulates:
✅ Calcifications – aluminum oxide specks: 0.54–0.16 mm
✅ Fibrous calcifications in ducts – nylon fibrils: 1.56–0.40 mm
✅ Tumor masses – PMMA discs: 2.00–0.25 mm thick
✅ Compressed breast – 42 mm equivalent (average glandular/adipose mix)

Technical data:
✅ Dimensions: 101.5 x 108.0 x 44.0 mm
✅ Total PMMA thickness: 36.75 mm
✅ Wax insert thickness: 7.25 mm
✅ PMMA contrast disc: 10 mm diameter, 4 mm thick
Complies with:
✅ ACR Mammography Accreditation Program (May 4, 2012)
✅ IEC 61223-3-2
✅ CE certified
✅ User manual included – with step-by-step testing and evaluation guidelines
What’s included:
✅ Pro-MAM Accreditation Phantom
✅ 2 months of free Diagnomatic access
✅ Durable carrying case
✅ Full documentation
Test with accuracy. Accredit with confidence.
Get the ACR-approved phantom built to meet the exact requirements of the ACR Mammography Accreditation Program.
Order your Pro-MAM Accreditation Phantom today and ensure your imaging system is ready to deliver.