ACR-Approved. Full-field coverage for digital mammography QA and accreditation testing.
Ensure your digital mammography system meets ACR Mammography Accreditation Program and IEC 61223-3-2 requirements with the Full Field Phantom – designed for comprehensive, full-field QA and accreditation testing.
This phantom is designed to simulate the appearance of real breast structures, including micro-calcifications, fibrous tissue in ducts, and tumor-like masses, enabling systematic verification of system performance across micro-calcification detection, spatial resolution, and contrast sensitivity.
Larger than the standard Pro-MAM Phantom, the Full Field (FF) version provides complete coverage of the image receptor, minimizing scatter and enhancing the accuracy of system evaluation.
What if ACR accreditation could be faster, simpler, and fully documented?
That’s exactly what Diagnomatic is built to deliver. Our QA automation platform takes the complexity out of the process so you can focus on what really matters, your patients.

With Diagnomatic, you can:
✅ Complete QA evaluations automatically – no manual measurements
✅ Instantly generate reports compliant with ACR Mammography Accreditation Program and IEC 61223-3-2
✅ Keep all results securely stored online and accessible anytime
✅ Reduce documentation time, minimize human error, and maintain consistent compliance records
Diagnomatic works seamlessly with the Pro-MAM Accreditation FF phantom, giving you everything you need to approach accreditation with confidence.
👉 Buyers of the Pro-MAM Accreditation FF phantom get 2 months of Diagnomatic access free, so you can streamline reporting and compliance from day one.
Key Benefits:
✅ Full detector coverage – ideal for large-format digital mammography systems
✅ ACR-Approved & CE certified – ensures regulatory compliance and readiness for accreditation
✅ Clinically realistic simulation – replicates a 42 mm compressed breast with 50/50 glandular/adipose composition
✅ Evaluates micro-calcification detectability down to 0.14 mm and ductal structures down to 0.30 mm
✅ Protective carrying case included – easy transport and storage
✅ Customizable to your specifications
Simulates:
✅ Micro-calcifications – aluminum oxide specks: 0.32–0.14 mm
✅ Fibrous structures – nylon fibrils: 0.89–0.30 mm
✅ Tumor-like masses – PMMA: 1.00–0.20 mm thick

Technical Data:
✅ Dimensions: 311.2 x 190.5 x 41.3 mm
✅ Simulated breast thickness: 42 mm, 50% glandular / 50% adipose
✅ Wax insert with precision-placed targets
✅ Protective carrying case included
Standards Compliance:
✅ ACR Mammography Accreditation Program Requirements
✅ IEC 61223-3-2
✅ CE Certified
✅ Detailed user manual included – with clear guidelines for test execution and results assessment
Full-field validation. ACR-compliant results.
Get the ACR-approved phantom built to meet the exact requirements of the ACR Mammography Accreditation Program.
Order your Full Field Mammography Phantom today and ensure your system meets ACR Mammography Accreditation Program requirements.